logo
ニュース詳細
ホーム / ニュース /

会社のニュース Silicone, Spring, Float or Water Seal: Four Trap Designs Compared

Silicone, Spring, Float or Water Seal: Four Trap Designs Compared

2026-11-20

Four trap designs solve the same problem — keeping sewer gas out while letting water through — and they differ in one respect: what force pushes the seal closed. A water seal uses gravity on a standing column. A silicone membrane uses the elastic recovery of a flap. A spring cartridge uses stored energy in a compressed spring. A float core uses buoyancy on a ball. Every practical difference between them, from service interval to failure mode, follows from that choice.

Which design is better depends on which closing force survives your floor: how often it gets wet, what reaches the grate, and whether anyone will lift the core out to clean it.

Why the four designs are not interchangeable

All four open under flow and re-seal afterwards. What separates them is how reliably they re-seal over years, and what maintenance keeps them sealing.

Design Closes by Dries out? Main wearing part
Water seal (cup / U-bend) Gravity on trapped water Yes, if unused None moving; the bend silts up
Silicone membrane Elastic recovery of the flap No Membrane lip and hinge line
Spring cartridge Spring force on a disc and gasket No Spring and gasket
Float core Buoyancy lifting a ball onto its seat No Ball surface and seat ring

The designs that cannot dry out need parts to keep moving; the one with no moving parts fails silently when the floor is idle.

Water seal: the reference design where the floor is used daily

A water seal holds a column of water deep enough to resist sewer gas pressure, and depth is what matters; the recognised benchmark for trap seal depth in sanitary waste systems is 50 mm. A trap that does not hold that column is not doing the job, however well it drains.

The seal is water, so it evaporates. A guest bathroom used two weeks a year, a balcony drain that only sees air-conditioning condensate, or a floor drain in a seasonal building will be dry for most of its life — and a dry trap is an open pipe. The trap also needs depth below the finished floor, which a thin screed often cannot give.

Wins on hotel bathrooms in daily use, hospital wet rooms and staff showers. Loses on anything intermittent.

Silicone membrane: closes fastest, but only if the lip stays clean

A membrane opens a few degrees under the weight of water and snaps shut by its own elasticity. No standing water, so no evaporation; it fits a shallow body and closes almost immediately.

The service reality is narrower. A membrane seals on a fine lip, and that lip has to meet its seat cleanly. Soap scum, hair, biofilm and grease hold it open by a fraction — enough to leak odour continuously while looking normal from above. Silicone hardness also drifts with hot water and aggressive chemicals, so a membrane that snapped shut when new can go soft after a year of daily washing.

The hinge must also sit upstream. Fit the flap the wrong way and flow inverts it, and an inverted membrane stays open.

Wins on showers with hair loading, secondary bathrooms, balcony drains and shallow retrofits. Loses in commercial kitchens and on floors cleaned with strong caustic.

Spring cartridge: best back-pressure behaviour, shortest service interval

A light spring presses a disc and gasket onto a seat; water pressure lifts the disc and the spring closes it. A mechanical, directional closing force resists back pressure and suds better than a membrane, works in any orientation, and cannot dry out.

The spring is also the wearing part, and it wears invisibly. Grit in the guide, scale on the stem and fatigue all reduce closing force gradually. The core does not fail open with a bang; it rests a fraction off its seat, and the symptom is a faint smell nobody can trace to a drain.

Wins where flow is intermittent and back pressure is real, or where a water seal will not fit. Loses in gritty environments without maintenance, because a jammed guide holds the disc open.

Float core: excellent against backflow, unforgiving about grit

A float core seals when water lifts a ball onto a seat ring, and opens when the water drains and the ball drops away. It is primarily a backflow defence: when the line surcharges, the ball rises and closes instead of letting sewage up through the grate.

Buoyancy is a weak force compared with a spring, and it only works if the ball moves freely and the seat ring is clean. One piece of grit under the ball, or a film of soap and hair around it, holds it off centre and the seal leaks. In showers the ball is the part most likely to be furred and stuck, and the least likely to be checked.

Wins on basement and ground-floor drains exposed to surcharge, garage and plant-room floors. Loses on anything with hair, grease or sediment.

Matching design to floor condition

The useful comparison is design against floor, not design against design.

Floor condition Seal that holds up Why
Hotel bathroom, daily use Water seal Water renewed constantly; no wearing parts
Guest bathroom, seasonal Silicone membrane No evaporation, closes without water
Balcony or AC condensate Silicone membrane Intermittent, shallow, must not dry out
Commercial kitchen Water seal plus grease separation Membranes and floats both foul with grease
Shower with long hair Membrane with a basket upstream The basket decides the service interval
Ground floor at surcharge risk Float or spring with backflow seat Closing force must resist reverse pressure
Warehouse washdown Water seal in a deep body High flow, high sediment, routine cleaning

Two rules survive every row: keep hair and grit out before they reach the seal, and make the core removable from above without tools. A core that cannot be lifted out in seconds will not be cleaned.

What to put on the purchase order

"Anti-odour core" is not a specification — all four designs are anti-odour on the day they are installed and diverge afterwards. The order should state the seal principle explicitly; the seal depth required, referenced to the applicable standard; that the core is removable from above by hand without dismantling the grate frame; that it is interchangeable with the body series, so a floor can be re-specified later without breaking out the body; and the body and core materials separately, because the visible part and the working part are rarely the same alloy.

Where our bodies and cores sit in this comparison

We make the two halves separately: the body is fixed by the slab and the finish, the core is chosen by the floor condition. Our brass B floor drain core is its own part number within a core range, so a body can be specified once and re-cored later if the room changes use.

On the drain side, the BQ20151-D brass floor drain and the BQ20157-Q brass floor drain are both built around a removable core in a machined brass body. Brass is used because it machines cleanly at the seat face — and a clean seat face is what all four designs depend on.

Start from the floor's wetting pattern, not the catalogue. Daily wetting points to a water seal, intermittent wetting to a membrane, backflow risk to a float or spring seat, and heavy grease or sediment to a water seal with separation upstream. Tell us the room type, how often the floor is washed and what reaches the drain, and we will send the matching core set with the bodies that accept it — the quote form on any product page reaches the team that builds them.